| Switches : | Microprocessor based Touch Panel for Blower, LED light & UV light. (UV light with Timer). Motorized Front door of toughen glass |
| Pre-filter : | 90.00%, down to 5 micron |
| HEPA Filter : | ISO 14644 Class 5 (Class 100). 99.97%-99.99% down to 0.3 micron. Mesh guard for protection of HEPA Filter. |
| Airflow : | Top to downward |
| Noise Level : | 60 decibel ± 5%.. |
| Velocity : | 0.35-0.50m/sec |
| Work Table : | Made up of Stainless Steel 304grade (Perforated). Cock for gas on work table. |
| Front door: | Made of Toughen glass. (Motorized) |
| UV Lamp : | 15/30W, make Philips Holland |
| Illuminationr: | LED Lights for easy operation. |
| Pressure: | Digital Manometer 0-50mm range with filter failure alarm. |
| Power Supply : | 230V ± 10V/50Hz single phase A.C. |
| Cabinet: | Cabinet made of 304 grade Stainless Steel. |
| Electricals: | 15/5 AMP socket with switch. |
| Heavy Duty Blower: | Dynamically balanced with 0.25 HP Electric Motor Mounted on anti vibration pad1440rpm motor. |
| Safety Features : | Voltage fluctuations Protection. Micro switches for UV & LED Lights. |
| Stand : | Castor Wheels for easy movability. Front Wheels lockable with brakes. |
- RH-56-05 Working area Size 60x60x60 cm.
- RH-56-06 Working area Size 90x60x60 cm.
- RH-56-07 Working area Size 120x60x60 cm.
- RH-56-08 Working area Size 150x60x60 cm.
Description
Vertical Laminar Air Flow Workstation – Stainless Steel HEPA H14 Hood
Available sizes: RH‑56‑05, RH‑56‑06, RH‑56‑07, RH‑56‑08 • Lead time: Contact for current stock
What Is a Vertical Laminar Flow Cabinet? Applications & Use‑Cases
Vertical Laminar Air Flow Workstations are widely used where product protection and particulate‑free environments are essential. In pharmaceutical QA/QC and sterile product assembly, the vertical configuration directs HEPA‑filtered air top‑to‑bottom to sweep particulates away from critical zones, making it ideal for visual inspection, weighing, vial filling and packaging tasks that require minimal contamination risk.
Microbiology and Tissue Culture
For microbiology labs and tissue culture work, the vertical laminar profile offers a protected workspace for aseptic manipulation of cultures, media preparation and sample transfer. Combined with the HEPA H14 filter and optional UV chamber sterilization between runs, the cabinet supports workflows for cell culture, PCR setup and sensitive analytical sample handling, reducing cross‑contamination risk and improving reproducibility.
Electronics and Precision Assembly
Electronics assembly and laboratory electronics testing benefit from laminar flow’s particle control. Although horizontal workstations can offer ergonomic advantages for long tasks, vertical units protect delicate components from settling dust during visual inspection and soldering prep. Use cases include PCB inspection, optical component assembly and clean sub‑assembly stations inside larger cleanroom workflows.
Clinical, IVF and Diagnostic Labs
IVF clinics, diagnostic labs and histology units use vertical laminar flow workstations for sample preparation, staining and non‑hazardous specimen handling. The stable laminar profile and compact footprint make vertical cabinets suitable for bench‑level installations where floor space is constrained but high cleanliness is required.
When to Choose Vertical vs Horizontal
Choose vertical laminar flow when product protection is the top priority and the process involves open‑surface handling or particulate‑sensitive tasks. Choose horizontal laminar flow when operator comfort and face‑level access are more important and the task benefits from back‑to‑front airflow. For mixed workflows, we recommend assessing sample type, operator ergonomics and available footprint — our technical team can recommend the optimal configuration and size for your lab.
Want a tailored recommendation? Use the Request a Quote link and include your workflow, dimensions and sample type — we’ll reply with a recommended model, configuration and lead time.
Vertical vs Horizontal Laminar Air Flow Workstations
| Feature | Vertical Laminar Air Flow | Horizontal Laminar Air Flow |
|---|---|---|
| Airflow Direction | Top to bottom | Back to front |
| Best For | Product protection; pharma; microbiology | Sample handling; electronics; ergonomics |
| Space Requirement | Compact footprint | Requires more depth |
| User Comfort | Airflow may cause draft on hands | More comfortable for long tasks |
| Typical Applications | Pharma QC; microbiology labs | Electronics assembly; IVF labs |
Both models provide ISO Class 5 clean air. Choose based on your workflow, space and ergonomic needs. For help selecting the right model, contact our technical team.
Technical Snapshot
- HEPA filter: H14
- Digital manometer (0–50 mm) with alarm
- UV lamp: Philips with timer
- Finish: Stainless Steel (SS)
- Sizes: RH‑56‑05, RH‑56‑06, RH‑56‑07, RH‑56‑08
Technical Specifications (HEPA, UV Lamp, Air Flow, Manometer)
The Vertical Laminar Air Flow Workstation is engineered for reliable product protection and consistent ISO Class 5 cleanliness. Core features include a certified HEPA H14 filtration stage ensuring >99.995% particle removal at 0.3 µm; a digital manometer with 0–50 mm range and audible/visual alarm to monitor filter performance; and an energy‑efficient motor/fan assembly optimised for stable laminar profile and low vibration. The cabinet body and work surface are finished in durable stainless steel to meet laboratory hygiene and corrosion resistance requirements.
- Filtration: HEPA H14 primary, optional pre‑filter for extended HEPA life.
- Controls: Digital manometer, timer‑controlled Philips UV lamp, and simple on/off controls for fan and light.
- Construction: Powder‑coated exterior with 304/316 stainless steel work area; modular panels for easy service and filter change.
- Sizes & Options: Available RH‑56‑05 → RH‑56‑08; custom sizes on request; optional motorised sash and exhaust configurations.
- Compliance & Safety: ISO Class 5 airflow profile, filter failure alarm, and easy access for maintenance.
These features reduce contamination risk, simplify maintenance and shorten commissioning time for QC, microbiology and production environments. For full specifications and filter performance curves, download the datasheet above or contact our technical team.
Laminar Flow Cabinet Price and Models in India (FAQ’s)
What is a Laminar Air Flow Workstation used for?
A Laminar Air Flow Workstation is used in laboratories, research centres and pharma facilities to provide an ISO Class 5 sterile, particle‑free environment for handling sensitive samples and experiments.
What is the difference between vertical and horizontal laminar air flow?
Vertical units direct clean air from top to bottom, protecting products from contamination. Horizontal units direct air from back to front and are more ergonomic for prolonged operations.
What is the price range of a Laminar Air Flow Workstation in India?
Rescholar’s Vertical Laminar Air Flow Workstations start at approximately ₹40,000. Exact pricing depends on size and specifications — request a quote for customised pricing.
Does the workstation include UV light?
Yes. The workstation includes a Philips UV lamp with timer control for sterilisation. UV should only be used when the workstation is unoccupied.
What is the pressure range in a laminar air flow workstation?
The workstation is equipped with a digital manometer with a 0–50 mm range and filter failure alarm to ensure consistent airflow and safety.
Can I order custom sizes or finishes?
Yes. We offer custom sizes and stainless steel finishes. Contact us with your dimensions and requirements for a tailored quotation.
Get a Quote Today
Rescholar’s Vertical Laminar Air Flow Workstations start at ₹40,000. Contact us for a customised quotation based on size and specifications.
Quick response within 24 hours • Nationwide delivery available
✅
ISO 9001 Certified
🚚
Global Delivery
🛠️
1 Year Warranty
📞
24/7 Support